Observe these guidelines for use of the DIP switches:
– Out of the box, all three switches are in the Off position. In this state, the tap is configured to be a non-supervisor ring node and will respond to the default IP
address of 169.254.1.1. If your application does not require access to the tap’s diagnostic information or configuration, no further action is required. Otherwise,
select alternate DIP switch settings or configure the tap by using RSLinx Classic software or the Studio 5000 Logix Designer application.
– When a switch is pushed to the left, it is in the Off position.
– When a switch is pushed to the right, it is in the On position.
– position

Category:
  • Email:cindy@justwellcenter.com
  • Phone:+86 13376981664
  • Whatsapp:+86 13376981664
  • Amy

Description

Brand:Allen-Bradley   Model number:1783-ETAP2F

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:2.5kg

Product Dimensions:

To use RSLinx® Classic communication software to configure the tap, follow these steps to download the EDS file for the tap.
1. Obtain the EDS file from rok.auto/pcdc.
2. From the Network pull-down menu, choose the EtherNet/IP™ network.
3. From the Device Type pull-down, choose Communication Adapter.
4. In the Bulletin/catalog number field, type 1783-ETAP.
5. Click Search.
6. Click Download to download the EDS file for the tap.
7. Save the file to an appropriate location on your computer.
8. Use your configuration software to register the downloaded file.
If you are using RSLinx Classic communication software, use the EDS Hardware Installation Tool.
Choose Start > All Programs > Rockwell Software > RSLinx > Tools.
Configure Internet Protocol Settings
Configure Internet Protocol (IP) settings, such as the IP address, in one of these ways:
• Use the tap’s default IP address of 169.254.1.1 by connecting the tap directly to a computer. To establish communication between a computer and the tap’s default IP
address, you have the following options:
– Enter a unique IP address in the local area connection properties for your computer. The computer’s IP address must be on the same subnet as the tap’s default
IP address, such as 169.254.1.2.
– Configure your computer to obtain its IP address automatically.
• Use IP settings that are configured in RSLinx Classic software or the Studio 5000 Logix Designer application.
• Acquire IP settings from a DHCP server.
• Acquire IP settings from a BOOTP server.
Use the DIP switches on the tap to select the configuration method to use for IP settings. Refer to Set the DIP Switches on page 9.
Use the DHCP/BOOTP Server
If your network infrastructure does not provide DHCP/BOOT functionality, you may download our DHCP/BOOTP server software to a personal computer running a Microsoft
Windows® operating system. You can use this computer as the DHCP/BOOTP server.
To set the network address by using the Rockwell Automation DHCP/BOOTP server, follow these steps.
1. Access the DHCP/BOOTP utility at https://ab.rockwellautomation.com.
2. Download the version 2.3.2 DHCP/BOOTP utility.
3. Extract the zipped files to a temporary directory.
4. In the temporary directory, double-click setup.exe to install the DHCP/BOOTP utility.
5. Run the utility.
6. See the following chart, which describes what happens next, depending on whether DHCP/BOOTP is enabled on the tap.
Set the DIP Switches
Use the DIP switches on the tap to do the following:
• Specify the method for configuring Internet Protocol (IP) settings, such as the IP address.
• Enable the Ring Supervisor mode with its current parameters.
• Restore the factory default settings.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

AB 1746-OB16
AB 1746-OB16E
AB 1746-OB32
AB 1746-OB32E
AB 1746-OB8
AB 1746-OBP16
AB 1746-OG16
AB 1746-OV16
AB 1746-OV32
AB 1746-OW16
AB 1746-OW16/C
AB 1746-OW16/C/D
AB 1746-OW4
AB 1746-OW8
AB 1746-OX8
AB 1746-P1
AB 1746-P2
AB 1746-P2/C
AB 1746-P3
AB 1746-P4
AB 1746-P5
AB 1746-P6
AB 1746-P7
AB 1746SC-NI8U
AB 1746SC-OAP8I
AB 1747-ACN15
AB 1747-ACNR15
AB 1747-ACNR15/A
AB 1747-ASB
AB 1747-ASB/A
AB 1747-ASB1747-L511
AB 1747-BA
AB 1747-BSN
AB 1747-BSN1771-IFE
AB 1747-CP3/A
AB 1747-DCM
AB 1747-KE
AB 1747-KFC15
AB 1747-L30C
AB 1747-L40F
AB 1747-L511
AB 1747-L511/B
AB 1747-L514
AB 1747-L524
AB 1747-L524/C
AB 1747-L53
AB 1747-L531
AB 1747-L531/E
AB 1747-L531/L532/L533
AB 1747-L532
AB 1747-L532/D
AB 1747-L532/D/E
AB 1747-L532/E
AB 1747-L533
AB 1747-L541
AB 1747-L541/B
AB 1747-L541/B/C
AB 1747-L541/C
AB 1747-L542
AB 1747-L542/B
AB 1747-L542/C
AB 1747-L543
AB 1747-L543/C
AB 1747-L55
AB 1747-L551
AB 1747-L551/B
AB 1747-L551/C
AB 1747-L552
AB 1747-L552/C
AB 1747-L553
AB 1747-L553/B
AB 1747-L553/C
AB 1747-M1
AB 1747-M11
AB 1747-M12/A
AB 1747-M13
AB 1747-M15
AB 1747-M2
AB 1747-M4
AB 1747-NI4
AB 1747-PSD
AB 1747-SCNR
AB 1747-SDN
AB 1747-SN
AB 1747-SN17
AB 1747-UIC
AB 1756-0B16E
AB 1756-0F4
AB 1756-0X8I
AB 1756-A10
AB 1756-A13
AB 1756-A17
AB 1756-A4
AB 1756-A7
AB 1756-BA11
AB 1756-BA2
AB 1756-CFM
AB 1756-CN2
AB 1756-CN2/B
AB 1756-CN21
AB 1756-CN2R
AB 1756-CN2R/B
AB 1756-CNB
AB 1756-CNB/A/B/C/D
AB 1756-CNB/D
AB 1756-CNB/E
AB 1756-CNBR
AB 1756-CNBR/A/D
AB 1756-CNBR/D
AB 1756-CNBR/E
AB 1756-CPR2
AB 1756-DHRIO
AB 1756-DHRIO/C
AB 1756-DHRIO/D
AB 1756-DHRIO/E
AB 1756-DMD30
AB 1756-DNB
AB 1756-DNB/A
AB 1756-DNB/A/B
AB 1756-DNB/B
AB 1756-DNB/C1756-DNB/D
AB 1756-DNB/D
AB 1756-DNB1
AB 1756-EN2T
AB 1756-EN2T/C
AB 1756-EN2T/D
AB 1756-EN2TR
AB 1756-EN2TR/B
AB 1756-EN3TR
AB 1756-ENBT
AB 1756-ENBT/A
AB 1756-ENET
AB 1756-EWEB
AB 1756-HSC
AB 1756-HSC1
AB 1756-HYD02
AB 1756-IA16/A
AB 1756-IA32
AB 1756-IB16
AB 1756-IB16/A
AB 1756-IB16D
AB 1756-IB16I
AB 1756-IB16ISOE
AB 1756-IB16SOE
AB 1756-IB32
AB 1756-IB32/A
AB 1756-IF16
AB 1756-IF16/A
AB 1756-IF161
AB 1756-IF16H
AB 1756-IF4FXOF2F
AB 1756-IF6CIS
AB 1756-IF6I
AB 1756-IF8
AB 1756-IF8H
AB 1756-IF8U
AB 1756-IG16
AB 1756-IH16I
AB 1756-IM16I
AB 1756-IM16I1203-CN1
AB 1756-IN16
AB 1756-IR6I
AB 1756-IRT8I
AB 1756-IT6I
AB 1756-IT6I2
AB 1756-IV16
AB 1756-IV32
AB 1756-L1M1
AB 1756-L35E
AB 1756-L55M12
AB 1756L55M13
AB 1756-L55M13
AB 1756-L55M14
AB 1756L55M16
AB 1756-L55M16
AB 1756L55M22
AB 1756-L55M22
AB 1756L55M23
AB 1756-L55M23

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm