When the module is installed in Zone 22, the following cabinets must be used:
IVK-ISRPI-V16LC; IVK-ISRPI-V8HYW; or IVK-ISRPI-V8LC. These
cabinets can be purchased from Pepperl+Fuchs GmbH, Lilienthalstrasse 200,
68307 Mannheim, Germany. Information available at
www.pepperl-fuchs.com.
The IS-RPI cabinets (type IVK2-ISRPI-V8LC, IVK2-ISRPI-V8HYW, or
IVK2-ISPRI-V16LC) ensures the basic protection for the intrinsically safe
apparatus of the FLEX Ex system for use in Zone 22. It corresponds with
category 3D according to RL 94/9 EG and with the type label marked with
the following information:

Category:
  • Email:cindy@justwellcenter.com
  • Phone:+86 13376981664
  • Whatsapp:+86 13376981664
  • Amy

Description

Brand:Allen-Bradley   Model number:1797-IBN16

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:1.47kg

Product Dimensions:

1. Rotate keyswitch (1) on terminal base unit (2) clockwise to position 6
as required for this type of module.
Do not change the position of the keyswitch after wiring the
terminal base unit.
2. Make certain the flexbus connector (3) is pushed all the way to the left
to connect with the neighboring terminal base/adapter.
You cannot install the module unless the connector is fully extended.
3. Make sure the pins on the bottom of the module are straight so they
will align properly with the connector in the terminal base unit.
4. Position the module (4) with its alignment bar (5) aligned with the
groove (6) on the terminal base.
5. Press firmly and evenly to seat the module in the terminal base unit.
The module is seated when the latching mechanism (7) is locked into
the module.
6. Make certain that you only connect terminal base units to other
intrinsically safe system modules or adapters to maintain the integrity
of the intrinsically-safe backplane.
ATTENTION This equipment is considered Group 1, Class A industrial equipment according
to IEC/CISPR Publication 11. Without appropriate precautions, there may be
potential difficulties ensuring electromagnetic compatibility in other
environments due to conducted as well as radiated disturbance.
This equipment is supplied as open-type equipment. It must be mounted within
an enclosure that is suitably designed for those specific environmental
conditions that will be present and appropriately designed to prevent personal
injury resulting from accessibility to live parts. The interior of the enclosure
must be accessible only by the use of a tool. Subsequent sections of this
publication may contain additional information regarding specific enclosure
type ratings that are required to comply with certain product safety
certifications.
20128-M
FLEX Ex NAMUR Input Module 5
Publication 1797-IN007H-EN-P – August 2017
7. Remove cap plug (8) and attach another intrinsically safe terminal base
unit to the right of this terminal base unit if required.
Installation in Zone 1
This module must not be exposed to the environment. Provide a suitable
metal enclosure. This module has a protection factor of IP20.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

AB 1746-OB16
AB 1746-OB16E
AB 1746-OB32
AB 1746-OB32E
AB 1746-OB8
AB 1746-OBP16
AB 1746-OG16
AB 1746-OV16
AB 1746-OV32
AB 1746-OW16
AB 1746-OW16/C
AB 1746-OW16/C/D
AB 1746-OW4
AB 1746-OW8
AB 1746-OX8
AB 1746-P1
AB 1746-P2
AB 1746-P2/C
AB 1746-P3
AB 1746-P4
AB 1746-P5
AB 1746-P6
AB 1746-P7
AB 1746SC-NI8U
AB 1746SC-OAP8I
AB 1747-ACN15
AB 1747-ACNR15
AB 1747-ACNR15/A
AB 1747-ASB
AB 1747-ASB/A
AB 1747-ASB1747-L511
AB 1747-BA
AB 1747-BSN
AB 1747-BSN1771-IFE
AB 1747-CP3/A
AB 1747-DCM
AB 1747-KE
AB 1747-KFC15
AB 1747-L30C
AB 1747-L40F
AB 1747-L511
AB 1747-L511/B
AB 1747-L514
AB 1747-L524
AB 1747-L524/C
AB 1747-L53
AB 1747-L531
AB 1747-L531/E
AB 1747-L531/L532/L533
AB 1747-L532
AB 1747-L532/D
AB 1747-L532/D/E
AB 1747-L532/E
AB 1747-L533
AB 1747-L541
AB 1747-L541/B
AB 1747-L541/B/C
AB 1747-L541/C
AB 1747-L542
AB 1747-L542/B
AB 1747-L542/C
AB 1747-L543
AB 1747-L543/C
AB 1747-L55
AB 1747-L551
AB 1747-L551/B
AB 1747-L551/C
AB 1747-L552
AB 1747-L552/C
AB 1747-L553
AB 1747-L553/B
AB 1747-L553/C
AB 1747-M1
AB 1747-M11
AB 1747-M12/A
AB 1747-M13
AB 1747-M15
AB 1747-M2
AB 1747-M4
AB 1747-NI4
AB 1747-PSD
AB 1747-SCNR
AB 1747-SDN
AB 1747-SN
AB 1747-SN17
AB 1747-UIC
AB 1756-0B16E
AB 1756-0F4
AB 1756-0X8I
AB 1756-A10
AB 1756-A13
AB 1756-A17
AB 1756-A4
AB 1756-A7
AB 1756-BA11
AB 1756-BA2
AB 1756-CFM
AB 1756-CN2
AB 1756-CN2/B
AB 1756-CN21
AB 1756-CN2R
AB 1756-CN2R/B
AB 1756-CNB
AB 1756-CNB/A/B/C/D
AB 1756-CNB/D
AB 1756-CNB/E
AB 1756-CNBR
AB 1756-CNBR/A/D
AB 1756-CNBR/D
AB 1756-CNBR/E
AB 1756-CPR2
AB 1756-DHRIO
AB 1756-DHRIO/C
AB 1756-DHRIO/D
AB 1756-DHRIO/E
AB 1756-DMD30
AB 1756-DNB
AB 1756-DNB/A
AB 1756-DNB/A/B
AB 1756-DNB/B
AB 1756-DNB/C1756-DNB/D
AB 1756-DNB/D
AB 1756-DNB1
AB 1756-EN2T
AB 1756-EN2T/C
AB 1756-EN2T/D
AB 1756-EN2TR
AB 1756-EN2TR/B
AB 1756-EN3TR
AB 1756-ENBT
AB 1756-ENBT/A
AB 1756-ENET
AB 1756-EWEB
AB 1756-HSC
AB 1756-HSC1
AB 1756-HYD02
AB 1756-IA16/A
AB 1756-IA32
AB 1756-IB16
AB 1756-IB16/A
AB 1756-IB16D
AB 1756-IB16I
AB 1756-IB16ISOE
AB 1756-IB16SOE
AB 1756-IB32
AB 1756-IB32/A

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm