Description
MTL MTL3046B REPEATER POWER SUPPLY
Product Dimensions:
MTL3046B REPEATERPOWER SUPPLY, 4/20mAfor ‘smart’ transmitters67 32 –+–+85 14 –+67 32–+ –+85 14 –+MTL3046BSmart transmitterHHC*20–35V dcHHC*20–35V dcMTL3046B*Hand-held communicator4/20mAOTHER APPLICATIONSAlthough designed for ‘smart’ transmitter applications, the MTL3046Boperates with standard analogue 4/20mA transmitters, and thereforecan be especially useful if upgrading later to ‘smart’ transmitters.The MTL3046B can be used to repeat a current generated byhazardous-area equipment in an existing barrier-protected safe-areacircuit, to provide a fully isolated output with a high load handlingcapability.The MTL3046B operating with an MTL3045 can pass measurementand control signals through a hazardous area separating two safeareas (see MTL3045).The frequency response of dc to 10kHz (hazardous to safe area)makes the MTL3046B ideal for some flowmeter applications such asvortex and turbine meters.4/20mA Load4/20mA Load4/20mAThe MTL3046B performs a similar function to the MTL3041, but istailored for use with ‘smart’ transmitters whose digital communicationsignals are superimposed on a standard 4/20mA analogue signal.The unit provides a minimum of 15V at 20mA to energise thetransmitter while at the same time repeating the current accurately ina separate circuit to drive a load in the safe area. The transmitter canbe calibrated, interrogated or tested from the host computer, or byusing a hand-held communicator connected in either the safe orhazardous area. The MTL3046B is a development of the MTL3046,which it replaces, and it is compatible with the majority of ‘smart’transmitters available.SPECIFICATIONSee also ‘Common specification’Number of channelsOne, fully floatingLocation of transmitterZone 0, IIC, T4–6 hazardous area if suitably certifiedDiv 1, Group A, hazardous locationVoltage available for transmitter and lines15V minimum at 20mANote: maximum open-circuit voltage is 28VMaximum permitted line resistance[(15 minus transmitter voltage requirement) x 50] ΩInput and output signal range4 to 20mA with superimposed digital signalDigital signal bandwidth (safe area to hazardous area)10Hz to 8kHzDigital signal bandwidth (hazardous area to safe area)dc to 10kHzInput resistance (terminals 6 & 8)≤30Ω (600mV at 20mA)Safe-area circuit load resistance20 to 750Ω (250Ω ±10% for digital communications)Safe-area circuit output resistance>1MΩSafe-area circuit ripple<160µA peak-to-peakDC transfer accuracy at 20°CBetter than 20µATemperature drift<1µA/°CResponse timeSettles to within 10% of final value after typically 40µsPower requirement85mA typically at 24V with 20mA signal75mA at 35V to 125mA at 20V with 20mA signalPower dissipation within unit1.7W typical at 24V with 20mA signal2.3W maximum at 35V with 20mA signalReplaceable fuse200mA, 5x20mm glass to DIN 41571 sht.2, semi-time-lag (M)Safety descriptionTerminals 5 & 628V, 300Ω, 93mA, Um = 250V rms or dcTerminals 6 & 8Non-energy storing apparatus – ≤1.2V, ≤0.1A, ≤20µJ and≤25mW. Can be connected without further certification into anyIS loop with open-circuit voltage not more than 28V.Note: Terminals 6 & 8 do not support bi-directional transmissions forHART®devices
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
AGILENT G2630-66015 |