Description
The F2-08DA-2 Analog Output module
provides several hardware features:
S Supports DL230, DL240, DL250–1
and DL260 CPUs (see firmware
requirements below).
S Analog outputs are optically
isolated from the PLC logic.
S The module has a removable
terminal block, so the module can
be easily removed or changed
without disconnecting the wiring.
The F2-08DA-2 requires a separate field-side power supply. Each module requires
21.6–26.4VDC at up to 140mA current. The DL205 bases have built-in 24 VDC
power supplies that provide up to 300mA of current. If you are using only a couple of
analog modules, you can use this power source instead of a separate supply. If you
want to use a separate supply, choose one that meets the power requirements of
your application.
Product Dimensions:
The F2-08DA-2 Analog Output module
provides several hardware features:
S Supports DL230, DL240, DL250–1
and DL260 CPUs (see firmware
requirements below).
S Analog outputs are optically
isolated from the PLC logic.
S The module has a removable
terminal block, so the module can
be easily removed or changed
without disconnecting the wiring.
S Can update all channels in one
scan (DL240, DL250–1 and DL260
only).
S Outputs are voltage sourcing.
S Outputs can be configured for
either of these ranges:
0 to 5 VDC
0 to 10 VDC
1)
2)
F2-08DA–2
+V3
+V4
+V5
+V6
+V7
+V8
Firmware Requirements:
To use this module, DL230 CPUs must
have firmware version 2.7 or later. To use
the pointer method of writing values,
DL240 CPUs require firmware version
3.0 or later and DL250 CPUs require
firmware version 1.33 or later.
The following tables provide the specifications for the F2-08DA-2 Analog Output
Module. Review these specifications to make sure the module meets your
application requirements.
Number of Channels 8, single-ended
Output Ranges 0 to 5V, 0 to 10V
Resolution 12 bit (1 in 4096)
Output Type Voltage sourcing
Peak Output Voltage 15VDC (clamped by transient voltage suppressor) Peak Output Voltage 15VDC (clamped by transient voltage suppressor)
Load Impedance 1kΩ (0–5V range); 10kΩ (0–10V range)
Load Capacitance .01μF maximum
Linearity Error (end to end) 1 count (0 025% of full scale) maximum Linearity Error (end to end) 1 count (0.025% of full scale) maximum
Conversion Settling Time 400 μs maximum (full scale change) Conversion Settling Time 400 μs maximum (full scale change)
4.5ms to 9ms for digital out to analog out
Full-Scale Calibration Error 12 counts max. @ 25°C (77°F) Full Scale Calibration Error
(offset error included)
12 counts max. @ 25 C (77 F)
Offset Calibration Error 3 counts maximum @ 25°C ( 77°F)
Accuracy vs Temperature 57 ppm/_C full scale calibration change Accuracy vs. Temperature 57 ppm/_C full scale calibration change
(including maximum offset change of 2 counts) (including maximum offset change of 2 counts)
Maximum Inaccuracy 0.3% @ 25°C (77°F) y @ ( )
0.45% 0–60°C ( 32–140°F)
PLC Update Rate 1 channel per scan maximum (Multiplexing)
8 channels per scan maximum (Pointer
[DL240/DL250–1/260 only])
Digital Outputs / 12 binary data bits, 3 ch. ID bits, 1 output enable Digital Outputs /
Output Points Required
12 binary data bits, 3 ch. ID bits, 1 output enable
bit / 16 (Y) output points required
Power Budget Requirement 60 mA @ 5VDC (supplied by base) Power Budget Requirement 60 mA @ 5VDC (supplied by base)
External Power Supply 24VDC (10%), 140mA (outputs fully loaded)
Operating Temperature 0 to 60° C (32 to 140° F) Operating Temperature 0 to 60° C (32 to 140° F)
Storage Temperature –20 to 70° C (–4 to 158° F)
Relative Humidity 5 to 95% (non-condensing)
Environmental Air No corrosive gases permitted
Vibration MIL STD 810C 514.2
Shock MIL STD 810C 516.2
Noise Immunity NEMA ICS3–304
One count in the specification table is equal to one least significant bit of the analog data value (1 in 4096).
The F2-08DA-2 analog output requires 16 discrete output points. The module can
be installed in any slot of a DL205 system, but the available power budget and
discrete I/O points can be limiting factors. Check the user manual for your particular
model of CPU and I/O base for more information regarding power budget and
number of local, local expanison or remote I/O points.
Your company may have guidelines for wiring and cable installation. If so, you
should check those before you begin the installation. Here are some general things
to consider:
S Use the shortest wiring route whenever possible.
S Use shielded wiring and ground the shield at the signal source. Do not
ground the shield at both the module and the load.
S Do not run the signal wiring next to large motors, high current switches,
or transformers. This may cause noise problems.
S Route the wiring through an approved cable housing to minimize the
risk of accidental damage. Check local and national codes to choose
the correct method for your application.
The F2-08DA-2 requires a separate field-side power supply. Each module requires
21.6–26.4VDC at up to 140mA current. The DL205 bases have built-in 24 VDC
power supplies that provide up to 300mA of current. If you are using only a couple of
analog modules, you can use this power source instead of a separate supply. If you
want to use a separate supply, choose one that meets the power requirements of
your application.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
AGILENT G2630-66015 |