Description
ABB TTH200-Y0 Temperature Transmitter
Product Dimensions:
Specifications
Change from one to two columns
1.1 Input
1.1.1 Resistance
RTD resistance thermometer
Pt100 in accordance with DIN IEC 60751, JIS, MIL,
Ni in accordance with DIN 43760, Cu
Resistance measurement
0 « 500 Ω
0 « 5000 Ω
Sensor connection type
Two-, Three-, Four-wire circuit
Connecting cable
Max. sensor line resistance (RW) for each line 50 Ω
according to NE 89 (March 2003)
Three-wire circuit:
symmetrical sensor line resistance
Two-wire circuit:
compensation up to 100 Ω total line resistance
Measurement current
< 300 µA
Sensor short circuit
< 5 Ω (for RTD)
Sensor wire break
Measuring range: 0 … 500 Ω > 0.6 … 10 kΩ
Measuring range: 0 … 5 kΩ > 5.3 … 10 kΩ
Corrosion detection in accordance with NAMUR NE 89
3-wire resistance measurement > 50 Ω
4-wire resistance measurement > 50 Ω
Sensor error signaling
RTD sensor: Short circuit and wire break
Linear resistance measurement: Wire break
1.1.2 Thermocouples / Voltages
Types
B, E, J, K, L, N, R, S, T, U, C, D
Voltages
-125 … 125 mV
-125 … 1100 mV
Connecting cable
Maximum sensor line resistance (RW) for each wire: 1.5 kΩ, total:
3 kΩ
Sensor wire break monitoring in accordance with NAMUR NE 89
Pulsed with 1 µA outside measurement interval
Thermocouple measurement 5.3 … 10 kΩ
Voltage measurement 5.3 … 10 kΩ
Input resistance
> 10 MΩ
Internal reference point
Pt1000, DIN IEC 60751 Cl. B
(no additional jumpers necessary)
Sensor error adjustment options (sensor matching)
Via single-point adjustment (offset adjustment)
Via two-point adjustment
Sensor error signaling
Thermocouple: Wire break
Linear voltage measurement: Wire break
1.2 Output
Transmission characteristics
Temperature linear
Resistance linear
Voltage linear
Output signal
Configurable 4 … 20 mA (standard)
Configurable 20 … 4 mA
(NE 43 dynamic range: 3.8 … 20.5 mA)
Simulation mode
3.5 … 23.6 mA
Induced current consumption
< 3.5 mA
Maximum output current
23.6 mA
Configurable error current signal
Override 22 mA (20.0 « 23.6 mA)
Underdrive 3.6 mA (3.5 « 4.0 mA)
1.3 Power supply (polarity safe)
Change from one to two columns Speisespannung
Two-wire circuit; power lines = signal lines
Supply voltage
Non-hazardous area with or without LCD display:
US = 11 … 42 V DC
hazardous area applications with or without LCD display:
US = 11 … 30 V DC
Max. permissible residual ripple for supply voltage
during communication in accordance with HART FSK “Physical
Layer” specification, version 8.1 (08/1999) Section 8.1
Undervoltage detection
UTerminal-Mu < 10 V results in Ia = 3.6 mA
Maximum load
RLoad = (supply voltage – 11 V) / 0.022 A
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
ABB | 07DC92 GJR5252200R0101 | ABB | 5STP2665N0024 |
ABB | 07KT98 GJR5253100R0270 | ABB | 5STP27H1800 |
ABB | 07LE90 | ABB | 5STP27H2801 |
ABB | 100-250V50/60HZ-D | ABB | 5STP2842L0024 |
ABB | 100-250V50/60HZ-DC | ABB | 5STP28L4200 |
ABB | 100-250V50/60HZ-DC | ABB | 5STP3328L0003 |
ABB | 10332-00505 | ABB | 5STP3328L0005 |
ABB | 10332-00655 | ABB | 5STP3328L0011 |
ABB | 120M8-NT-6 | ABB | 5STP34H1601 |
ABB | 19160/29160N ASC-29160N/DELL2 | ABB | 5STP38N4000 |
ABB | 19160/29160N ASC-29160N/DELL2 | ABB | 5STP38N4200 |
ABB | 1Q1SY-Cabled | ABB | 5STP4200 |
ABB | 1SAP250300R0001 AI523 | ABB | 5STP45N2800 |
ABB | 220V-230V50Hz | ABB | 5STP45Q2800 |
ABB | 24-30Vac/dc | ABB | 70M6-NT-6 |
ABB | 250Vac/dc | ABB | 95M8-NT-6 |
ABB | 35M6-NT-6 | ABB | A110-30-11*110V 50Hz/110-120V |
ABB | 38SC98000HR615 | ABB | A110-30-11*220-230V |
ABB | 3ASD573001A1 YPP110A | ABB | A12-30-10*220-230V |
ABB | 3ASD573001A13 | ABB | A145-30-11*110V |
ABB | 3ASD573001A13 YPK112A | ABB | A145-30-11*220-230V |
ABB | 3BHE024577R0101/PP C907 | ABB | A16-30-10*110V |
ABB | 3BSC980004R784 | ABB | A16-30-10*220-230V |
ABB | 3BSC980006R136 | ABB | A185-30-11*110V |
ABB | 3BSE018135R1 CI858K01 | ABB | A210-30-11*110V |
ABB | 3BSE020510R1 DO801 | ABB | A210-30-11*220-230V |
ABB | 3BSE022362R1 DI803 | ABB | A260-30-11*110V |
ABB | 3BSE022364R1 DO802 | ABB | A260-30-11*220-230V |
ABB | 3BSE024388R4 PFXA401SF | ABB | A26-30-10*110V |
ABB | 3GZF303135-3 | ABB | A26-30-10*220-230V |
ABB | 50Hz/110-120V | ABB | A300-30-11*220-230V |
ABB | 50Hz/230-240V | ABB | A30-30-10*220-230V |
ABB | 50HZ/230-240V | ABB | A40-30-10*220-230V |
ABB | 57310001-CC DSPC171 | ABB | A63-30-11*110V50/110-120V60HZ |
ABB | 57310001-CC DSPC171 | ABB | A63-30-11*220V-230V50Hz/230-240V60Hz |
ABB | 57310001-GP | ABB | A9-30-10*110V |
ABB | 5SHY3545L0010 3BHB013088R0001 | ABB | A9-30-10*220-230V |
ABB | 5STP 18H4200 | ABB | A9-40-00 |
ABB | 5STP03D6500 | ABB | A95-30-11*220-230V 50Hz/230-240V |
ABB | 5STP03X6500 | ABB | ACS150/310/355 |
ABB | 5STP04D4200 | ABB | ACS510 |
ABB | 5STP06D2800 | ABB | ACS550 |
ABB | 5STP08F6500 | ABB | ACS580 |
ABB | 5STP10D2303 | ABB | ACS880-01/04 |
ABB | 5STP12F4200 | ABB | ACS880-07 |
ABB | 5STP16F2200 | ABB | AF1250-30-11*100-250V |
ABB | 5STP16F2800 | ABB | AF145-30-11*100-250V |
ABB | 5STP16F2801 | ABB | AF185-30-11*100-250V |
ABB | 5STP18F1800 | ABB | AF260-30-11*100-250V |
ABB | 5STP18F1801 | ABB | AF265-30-11-13 |